Current transformer definition of current transformer by. But, as in the voltage transformer, some of the primary current or the primary ampereturns are utilized for magnetizing the core, thus leaving. Transformer, current an instrument transformer for the measurement and monitoring of large currents by means of standard measuring instruments and automatic control and monitoring devices. Current transformers cts are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. A current transformer is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current under normal conditions of operation and differs from it by an angle.
A current flowing in the primary coil generates a timevarying magnetic field in the core. A distinction is made between ac transformers usually. A transformer couples two circuits magnetically rather than through any direct connection. I 1 n 2 i 2 n 1 i 1 i 2 n 1 n 2 i 1 x n 1 i 2 x n 2 ampere lilitan selalu seimbang i1 i2. Typically current transformers consist of a silicon steel ring core wound with many. Model around small power transformers, with up to 63 mva and up to. It can be designed to step up or step down voltages and works on the magnetic induction principle. Transformer, current article about transformer, current. In other words we can say that the voltage, actually applied to the primary.
Voltage transformer how is voltage transformer abbreviated. It employed in electrical energy power system for stepping down the voltage of the system to some protected value which is often provided to low rating meter. But, keep in mind that as the reflected burden resistance becomes higher, your transformer will have more voltage drop and it will behave more like a voltage transformer. Voltage transformers are in most situations connected between phase. A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. There is no sharp border between a voltage and current transformer.
In other words, cts work at their best when they are connected to very low impedance burdens. Voltage transformer which is also called as a potential transformer. Damping of the ferroresonance in voltage transformers type range tjx. Cts current transformers pts potential transformers. Current transformers principle of operation of ct a current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. So that amount of current will flow across the inductor which can induce the same amount of the applied voltage. The basics of current transformers nk technologies. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load.
It can raise or lower the voltage in a circuit but with a corresponding decrease or increase in current. The basics of current transformers current sensors for. A current transformer is a type of stepup transformers while voltage transformer is a type of step down transformers. The difference is not in the phisical principle, just in the usage. Transformers are a necessary part of all power supplies. The voltage in the load loop is measured across rl and is induced in the load inductor by the source inductor. Electrical engineering multiple choice questions and answers. Ac voltage can be transformed to another voltage of the same frequency using a transformer. Current transformer definition is a transformer whose primary carries the whole of an alternating current to be measured or controlled and whose secondary is connected to a measuring or control device. Difference between current transformer,voltage transformer. A current transformer is a device which produces an alternating current in its secondary which is proportional to the alternating current in its primary. Indoor instrument transformers schneider electric belgie. The current through the source loop is given by is.
It also serves to insulate apparatus from the potential of the circuit that is being measured or monitored. Recommendations are provided by manufacturers see application guides. The constant current transformer 38 the constant voltage transformer 40 saturable reactor control of a. In the limiting case of zero burden impedance and a small zx2 i1. What is a voltage transformer and a current transformer. A secondary shortcircuit will cause the unit to overheat and fail in a very short period of time.
It employed in electrical energy power system for stepping down the voltage of the system to some protected value which is often provided to low rating. The voltage circuit is connected across the secondary winding. Primary winding of voltage transformer is connected across line whose voltage is to be measured. In principle, the only difference between a current transformer and a voltage transformer normal type is that the former is fed with a constant currentwhile the latter is fed with a constant voltage, where constant has the strict circuit theory meaning. Difference between current transformer and voltage. Electrical engineering multiple choice questions and.
Commonly used core materials are air, soft iron, and steel. Voltage transformer article about voltage transformer by. The word primary refers to the primary winding of a transformer. K tf values required in practice depend on relay type and design. Projects on transformer, distribution transformer, electrical transformer, current transformers, distribution transformers repairs, transformer oil, voltage.
Voltage transformer potential transformer these are used for measurement of high voltages using low range voltmeters. Voltage transformers are together with current transformers known as instrument transformers. Current transformers reduce high voltage currents to a much lower value and provide a. A voltage transformer is intended to present a negligible load to the supply being measured. Transformer, voltage an instrument transformer for stepdown of voltage in measurement and monitoring circuits. Each of these materials is suitable for certain applications. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the actual electrical current flowing in an ac. It is used to raise or lower voltage and current between one circuit and the other, and plays a major role in almost all ac circuits. Medium voltage switchboard system from 1 to 36 kv sepam protection relays masterpact protection switchgear from 100 to 6300 a trihal mvlv dry cast resin transformer from 160 to 5000 kva evolis mv vacuum switchgear and components from 1 to 24 kv.
Narrowprofile current transformer with a builtin converter, with an output of 0. A current transformer is a device that is used for the transformation of current from a higher value into a proportionate current to a lower value. Compare the results found in step 1 with those of step 3, and the. Current and voltage transformers may be freestanding devices, or they may be built inside the bushing of some power apparatus such as a circuit breaker or a power transformer with a grounded tank. Cts are basically stepup voltage transformers, on the other hand, these are stepdown transformers in view of current.
Which of the following does not change in a transformer. Scribd is the worlds largest social reading and publishing site. It transforms the high voltage current into the low voltage current due to which. Does a current transformer produce a proportional voltage. The current in the secondary coil always changes by the inverse of the ratio by which the voltage changes. The technical guide these technical guides help you comply with installation standards and rules i.
Cts provide isolation from the high voltage primary, permit grounding of the secondary for safety, and step down the magnitude of the measured current to a value that can be. Typically the ct ratios must be the same, but different ratios can be used with a. Can resistance change or am i missing something else. The power transformer is used to convert voltage using the number of windings in the two coils as ratio, while the current transformer is just an inductor placed around a wire to sense the magnetic field caused by the changing current. The operation of current transformer is similar to the conventional power transformer. Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as current transformer ct and lead. Potential transformers pts and current transformers cts. The low secondary voltage allows protective relay equipment and measuring instruments to be operated at a lower voltages. The output of the summing transformer is connected to the input of a wt series watt transducer. Current transformer basics and the current transformer. A current transformer is used to calculate current and power, to operate the protective relay and to monitor the power grid operation, etc. In mv electrical distribution, the high current and voltage values mean that they.
Doubling voltage and halving the current seems to completely contradict this basic law. Protection of single pole insulated voltage transformers against feroresonance phenom ena is stated in appendix 3. The instrument transformers like voltage transformer and current transformer are used for connecting the electrical instruments to the measuring instruments. When the circuit burden gets too large, the ct secondary voltage becomes.
If the voltage is raised to 10 times its original value by the transformer, the current in the secondary coil will be reduced to onetenth the value of the current in the primary coil. Calculation of cts if the current transformer has primary to secondary current ratio of 100. Chapter 25 electric power measurement and control systems. In other words, the polarizing voltage is 3 times the zerophase sequence. Generally, aircore transformers are used when the voltage source has a. Current and voltage transformer symbols and simplified concepts 5 i 1 i 2 v 1 v 2 symbol of a current transformer symbol of a voltage transformer conceptual picture of a current transformer. Allentown, pa abstract more and more substations are retrofitted with numerical relays, meters and monitoring devices. Transformer definition, a person or thing that transforms. Correct operation of currentcurrent, voltagevoltage, or currentvoltage devices usually depends on the relative instantaneous directions. All schneider electric instrument transformers are in conformity with iec. High short time current dan rating arus kecil lilitan amper kecil. Transformation ratio for voltage transformer primary. A transformer is a static or stationary piece of apparatus by means of which electric power in one circuit is transformed into electric power of the same frequency in another circuit.
The primary coil is connected to an ac voltage source. Jkm5c single ratio ansi metering class at 60hz continuous thermal rating factor. The transformer works on the principle of electromagnetic induction. Medium voltage products current and voltage instrument. For a primary current greater than 10 times the rated current, in other words here. Transformer core the composition of a transformer core depends on voltage, current, and frequency. The word monitored refers to the circuit under test or being measured. A current transformer also isolates the measuring instruments from what may be very high voltage in the monitored circuit. This fact ascertains that the current will not increase to an abrupt value. The transformer winding voltage ratio is directly proportional to the winding turns ratio. Current transformers principle of operation of ct a current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs.
470 631 984 1162 508 467 1531 1145 461 879 203 1347 997 1531 60 1369 587 945 944 200 1090 1171 832 202 875 347 1001 198 106 1246 441 982 453 128 322 363 689